MCOMDOL is electronic DOL Starterwith Inbuilt
GSM/GPRS technology, it’s Mobile starter with built in potation. Through MCOMDOLcan
operate Pump from anywhere or Local same as DOL starter.
Specifications
1. System
Settings
• Input Voltage (AC) : 250 – 470 VAC, 50 Hz
• On voltage (Cold Start): 250
VAC
• Auto Off voltage: 200 VAC
2.
Protections / Setting Parameters
Pump Current Range : 3 – 22 Amp.
Parameter |
Setting Range |
Default setting |
Trip Time Delay |
Display |
LED |
Phase Failure |
Fixed |
Fixed |
4 sec ± 1 sec |
SPP |
YES |
Reverse Phase |
Fixed |
Fixed |
4 sec ± 1 sec |
SPP |
YES |
Voltage Unbalance |
Fixed |
Fixed |
4 sec ± 1 sec |
SPP |
YES |
Current Unbalance |
20% – 70% |
50% |
4 sec ± 1 sec |
CUB |
YES |
Overload |
20% – 60% |
> 140 % |
15 sec |
OL |
YES |
Dry run |
60% – 95% |
< 75 % |
15 sec |
DRN |
YES |
High voltage |
450 – 500 V |
480 V ± 2 V |
Fixed |
HIU |
YES |
Low voltage |
180 – 350 V |
250 V ± 2 V |
Fixed |
LOU |
YES |
Extremely High Current |
Fixed |
26 Amps. |
3 sec |
EHC |
NO |
3.TimersSetting
Parameter |
Setting Range |
Default setting |
Display |
LED |
Power on Timer |
3 sec – 300 sec |
60 sec ± 3 sec |
PONT |
YES |
Motor ON Timer |
5 – 720 min |
OFF |
OFF |
YES |
Repeat Run Timer |
5 – 999 min |
OFF |
RRT |
YES |
Dryrun Auto Start Timer |
5 – 720 min |
OFF |
DRAT |
YES |
Clock Based 4 MTC Timer |
As per 24 Hours |
OFF |
OFF |
YES |
Cyclic Timer |
Clock 24 Hours |
OFF |
CYC |
YES |
4.
Monitoring Display
• Digital
Voltmeter : 180 – 520 V
• Digital
Ammeter : 3 – 22 Amp
5.Monitoring
Web and Mobile app:
·
Real
time monitoring for all parameters.
6.
Reset
• Resetting mode : Manual by OFF switch, SMS, WEB, Mobile
app.
7.
Output Relay Contact
• Relay
Mechanical life : 10 lac
operations
• Dielectric
Strength : 2.2 KV , 50 Hz for 1 min
8.
Enclosure & Mounting
• Enclosure
Material : MS powder coated Enclosure
• Mounting : Wall Mounting with 4 screw M4 × 15 mm
• Temperature : 5 to 60°C
• Humidity : Up to 90% RH
9.
Dimensions & Weight
• L × W × D (mm) : 300 x 160 x 74mm
• Power
Consumption : Less than 4 Watts
• Weights : 1.2kg
Connection
Diagram
INPUT 415 VOLT |
MOTOR OUTPUT |
||||||
|
|
Applications
Agriculture
Irrigation
Domestic
Copyright © 2024. MODERN COMMUNICATION TECHNOLOGY. All rights reserved.